Service Configuration Settings
The scale is configured from the factory to match the specified settings for each unit, as defined by the product
specifications and sales brochure. Modification of the setting can be accomplished by altering user configuration
settings P11-P19. Caution:
Configuration of the settings of your scale should be accomplished by a trained
service technician to ensure proper operation and accuracy. Configuration is not covered under warranty.
Setup Controls
0 = KG only ; 1 = LB only ; 2 = units key active KG
and LB
P12 0-7 7 Power On zero
0 = +/- 1% ; 1 = +/- 2% ; 2 = +/- 5% ; 3 = +/- 10% ; 4 =
+/- 20% ; 5 = +/- 50% ; 6 = +/- 100% ; 7 = no limitation
range
(00) = +/- 1% (06) = +/- 20% (12) = + 5%
(01 )= +/- 2% (07) = +/-no limit (13) = + 10%
(02 )= +/- 3% (08 )= + 1% (14) = + 20%
(03 )= +/- 4% (09) = + 2% (25) = + no limit
(04) =+/- 5% (10 )= + 3%
(05 )= +/- 10% (11) = + 4%
power on zero
0 = current weight ; 1 = calibration zero ; 2 = power off
zero point
within power on
0 = current weight ; 1 = calibration zero ; 2 = power off
zero point ; 3 = continuously display “0
- - - - -
“
0 = 0d AZT off ; 1 = +/- 0.25d, 2 = +/- 0.5d ; 3 = +/- 1d;
4= +/- 1.5d ;5= +/- 2d ;6 = +/- 3d; 7= +/- 4d; 8 = +/- 5d
0 = very weak; 1 = weak; 2 = standard; 3 = strong
P18 0 - 9 9 Weight stability 0 = +/- 0.5d ; 1= +/- 1d; 2= +/- 1.5d ; 3= +/- 2d; 4= +/-
3d ;5= +/- 4d ;6 = +/- 5d; 7= +/- 6d; 8 = +/- 7d; 9 = +/-
P19 0-9 1 Overload range
Full scale
0 = 0% ; 1 = +9d ; 2 = 101% ; 3 = 102% ; 4 = 405% ;
5 = 110% ; 6 = 120% ; 7 = 150%; 8 = 200%; 9 = no
Change flashed digits
Saves data and move down
to next Parameter setting
.