Page view 4
02/18/04 5
Configuration
All Serial Communication parameters are em-
bedded in a user menu consisting of 5 separate
menu selections, each with its own sub-menu of
choices. If your scale is connected by RS-232
serial communication lines to other equipment,
or you wish to disable the lb/kg key, you may
have to modify some or all of these parame-
ters. To modify these parameters, you must first
enter the USER MENU mode. Once there, four
of the front panel keys become directional navi-
gators to move around in the menus, and one
key is used to save or SET the selections. Com-
plete directions are found below.
To place the unit in USER MENU mode:
Turn the scale off.
While holding down the lb/kg
key, turn the scale back on.
When the display shows "A1",
the unit is in USER MENU mode,
and you can release the lb/kg
key. Shown at right are the
directional and SET key assign-
ments.
Zero Gr Net lb kg MotionTare
MODEL
SPD100
TRANSTRONIC SCALE CO.
CLASS
CAPACITY :
100x0.05 lb
50x0.02 kg
n
max=3000
SET
USER MENU CHART
A2 A3 A4 A5A1
Baud Rate
Data Bits,
Parity
Transmission
Mode
Serial Data Format Disable Lb/kg
Key
c d 0 1
8 7O 7E 7 0 1 2 3 4
1200
2400
4800
9600
To place the unit back into the NORMAL OPERATING mode, turn off the power to the unit.
With no keys held down, turn the power back on. All front panel keys will now return to
their normal mode of operation.
SETTINGS FOR USE WITH UPS ONLINE AND ONLINE OFFICE SOFTWARE
A1 = 9600
A2 = 7 o
A3 = don’t care
A4 = 4
A5 = 0